v1.2 (1-AUG-25)
- Synchronized Scene Commands
Grouped shades now move in sync when scenes are manually executed. Shades with the same move percentage now start and stop together for a smoother experience
- Specify Motor Address During Pairing
Pairing commands can now define the desired motor address. Useful for more controlled and advanced provisioning workflows
- BluFi Reset Commands
Added ability to reset the device remotely via BluFi as either a factory reset or provisioning reset. Simulates holding the physical pairing or reset button. Used for hub credentials reset function.
- Green Blinking LED for Matter Window
LED now blinks green when the Matter pairing window is open to give clear visual feedback
- Bug Fixes and Reliability Improvements
- Device Timer Top Rail Issue
Prevents non-TDBU motors from receiving invalid top rail commands. Null values for top rail or tilt in timer payloads are now ignored
- Curtain Motor Limit Setting Refactor
Limit change code for curtain motors has been cleaned up and simplified. Prepares for future support where motors with no set limits may be allowed to re-pair
- ARC TCP API Fixes
Fixes rare reboot issue by ensuring all callbacks are stopped before cron tasks are deleted. Improves responses for API commands like version, travel speed, unpairing, and deleting motors. Ensures factory reset also clears all shades from memory
- Factory Reset Timing Reliability
Factory reset now waits for 433 MHz communication to complete before erasing data. Fixes rare timing issue where shade data might not be deleted properly if the hub rebooted too early
- Improved DHCP Compatibility
Removed redundant ARP checks after IP assignment which were causing issues with some mesh routers. Fixes cases where IP assignment would fail due to incorrect ARP responses
- Shadow Post Retry Logic
If three consecutive shadow post acknowledgments fail, the hub now force reconnects. Improves cloud connection stability and reliability
- BluFi Name Update Fix
BluFi name updates now happen instantly without disconnecting. Fixes cases where the name would show up incorrectly or be delayed
- Ethernet Task Stability
Increased Ethernet receive task stack size (memory) to improve performance and prevent crashes
v1.1.0 (16-MAY-25)
Initial Firmware Release.